LA 0712BWC

LA 0712BWC

LA 0712BWC

Reversible air-to-water heat pump for outdoor installation. 12 kW heat output.

Comfortably heat and cool up to 260 sqm.

An impressive 260 sqm can be supplied with energy-efficient heat. The Hydro-Tower HWK 332Econ5S also enables domestic hot water preparation for up to 6 people in the home. Already integrated: the heat pump manager for control, a 300 l domestic hot water cylinder, a 100 l buffer tank, as well as three circulating pumps and the safety valve. This makes installation extremely easy and convenient. Ideal for newly built single family homes.

  • Low operating costs. High seasonal performance factors thanks to electronic expansion valve and high-performance evaporator.
  • Regulated cooling. Reversible heat pump for heating and cooling. Prepared for dynamic cooling (fan convection) and silent cooling (floor/wall/ceiling areas). Intelligent dew point regulation via the heat pump manager (e.g. with Smart-RTC+).
  • Minimal space requirement thanks to installation close to walls and compact dimensions – minimum clearance from the wall on the intake side 50 cm.
  • Reliable. Operational reliability via sensor monitoring of the refrigeration circuit with demand-based defrosting. Integrated thermal energy metering
  • Easy to install. In cases of installation close to a wall in buildings which do not have a cellar, the pipework can be guided directly inside. Hydraulic connection of the heat pump optionally possible at the side or at the bottom.
  • Flexible expansion options. Bivalent or bivalent-renewable operation, distribution systems with mixed and unmixed heating circuits (e.g. underfloor heating and radiators). Even more efficient room temperature control Smart-RTC+.
  • Technical Data.

    Heat output max. A7/W35 | COP A7/W35: 11,3 kW | 4,8


    Energy efficiency class* with 35 °C flow temperature: A++


    Cooling capacity A27/W18: 8,6 kW


    EER A27/W18: 3,7


    Lower operating limit heat source (heating operation): -22 Grad


    Upper operating limit heat source (heating operation): 35 Grad


    Lower operating limit heat source (cooling operation): 15 Grad


    Upper operating limit heat source (cooling operation): 40 Grad


    Max. flow temperature: 60 Grad


    Sound pressure level in 10 m: 30 dB(A)


    Sound pressure level in 10 m (lowered operation): 28 dB(A)


    Width: 910 mm


    Height: 1650 mm


    Depth: 750 mm


    Weight: 265 kg



    Always up-to-date.

    Are you interested in regular maintenance or inspections on your system?

    We are there for you.

    Would you like more information on our products or do you have a question?

    We will be happy to help.